Data Center & Engineering

Design and implementation of engineering systems for data centers and server rooms. Power, cooling, fire suppression, access control, and CCTV — all required for reliable mission-critical infrastructure.

UPS Eaton/APC Diesel Generator Precision Cooling In-row Cooling FM-200 VESDA Access Control CCTV

Capabilities and Expertise

Uninterruptible Power Supply (UPS)

Single-phase and three-phase UPS systems from Eaton, APC/Schneider, and Vertiv. Online topology for maximum protection, capacity sizing based on load, bypass configuration, and N+1 redundancy.

Power Distribution (PDU / ATS)

Rack PDUs with power monitoring, automatic transfer switches for dual power source redundancy, and power mapping for server rooms and racks.

Precision Cooling

CRAC and CRAH systems from Schneider, Vertiv, and Stulz. In-row cooling for high-density racks, thermal load calculation, hot/cold aisle containment, and continuous temperature and humidity monitoring.

Fire Suppression Systems

Gas-based fire suppression systems such as FM-200, Novec 1230, and inert gases for server environments without equipment damage. Early smoke detection with VESDA and integration with alarm and evacuation systems.

Access Control and CCTV

Access control systems for data center facilities: card readers, PIN, and biometric verification. CCTV surveillance with video recording, perimeter control, and visitor log tracking.

DCIM and Engineering Monitoring

Data Center Infrastructure Management platforms for monitoring power, cooling, and environmental conditions. Alerting, reporting, capacity planning, and integration with network monitoring systems.

Delivery Process

01
Design

Load calculations, power and cooling схемes, and 3D room layout planning.

02
Engineering Works

Installation of cable routes, placement of equipment, and execution of engineering connections.

03
Commissioning

Configuration and testing of all engineering systems, including measurement of critical parameters.

04
Maintenance

Scheduled maintenance, UPS and battery inspection, and cooling system service.

Typical Client Scenarios

  • Construction of a new server room or data center
  • Expansion of an existing data center
  • Improving resilience with N+1 or 2N redundancy
  • Preparation for Tier II / III data center certification
  • Technical maintenance and audit of engineering systems
Do you have a similar task?

Send us a short description — we will provide an initial assessment and possible options within one business day.

Initial consultation is free

Other Softline IT Services

Have a task? Let’s discuss it.

Initial consultation is free. We respond within one business day.