Engineering Infrastructure

Data Center & Engineering

Design and implementation of engineering systems for data centers and server rooms. Power, cooling, fire suppression, access control, and CCTV — all required for reliable mission-critical infrastructure.

  • UPS Eaton/APC
  • Diesel Generator
  • Precision Cooling
  • In-row Cooling
  • Clean Agent
  • VESDA
  • Access Control
  • CCTV
What we do

Capabilities and Expertise

Uninterruptible Power Supply (UPS)

Single-phase and three-phase UPS systems from Eaton, APC by Schneider Electric, and Vertiv. Online double-conversion topology for maximum protection, power and runtime sizing based on load, VRLA or Li-ion batteries, and coordination with diesel generators. Bypass configuration and parallel UPS operation for N+1 redundancy.

Power Distribution (PDU / ATS)

Managed rack PDUs with power monitoring (Eaton, Raritan), automatic transfer switches for dual power source redundancy, and power mapping for server rooms and racks.

Precision Cooling

CRAC and CRAH precision air conditioning from Schneider Electric, Vertiv, and Stulz. In-row cooling for high-density racks, thermal load calculation, hot/cold aisle containment, energy-efficient operating modes, and continuous temperature and humidity monitoring.

Fire Suppression Systems

Gas-based fire suppression for server environments without equipment damage: inert gases (IG-541, IG-55) or FK-5-1-12 (known as Novec 1230); HFC-227ea (FM-200) only where current F-gas restrictions still allow it. Aspirating very early smoke detection with VESDA and integration with alarm and evacuation systems.

Access Control and CCTV

Access control systems for data center facilities: card readers, PIN, and biometric verification. IP video surveillance with recording, perimeter control, and visitor log tracking.

DCIM and Engineering Monitoring

Data Center Infrastructure Management platforms for monitoring power, cooling, and environmental conditions. Alerting, reporting, capacity planning, and integration with network monitoring systems.

How we work

Delivery Process

  1. 01

    Design

    Load calculations, power and cooling diagrams, and a 3D room model.

  2. 02

    Engineering Works

    Installation of cable routes, placement of equipment, and execution of engineering connections.

  3. 03

    Commissioning

    Configuration and testing of all engineering systems, including measurement of critical parameters.

  4. 04

    Maintenance

    Scheduled maintenance, UPS and battery inspection, and cooling system service.

When this is relevant

Typical Client Scenarios

  • Construction of a new server room or data center
  • Expansion of an existing data center
  • Improving resilience and autonomy: N+1 or 2N redundancy and operation during prolonged power outages
  • Preparation for Tier II / III data center certification (Uptime Institute)
  • Technical maintenance and audit of engineering systems

Have a task? Let’s discuss it.

Initial consultation is free. We respond within one business day.